ZohgoCheck an address free

Permitted Obstructions: What Can Go in a Required Yard in NYC

What is allowed in a required yard in NYC zoning?

Nothing may be built above ground in a required yard except the permitted obstructions the Zoning Resolution lists (ZR 23-313). Each comes with a cap: eaves 16 inches or 20 percent of the yard width, chimneys 3 feet, front-yard fences 4 feet, rear-yard sheds 10 feet tall, mechanical equipment 25 percent of the yard, and balconies 7 feet deep or one third of the yard (ZR 23-311, 23-312, 23-341, 23-62). Check your district and its yard rules free on Zohgo.

Yard depth is only half the question. The other half is what you are allowed to put in that yard, and the Zoning Resolution answers it with a precise list of permitted obstructions, each with its own size limit.

Yards are open space, with a fixed list of exceptions

Once a lot's front, side and rear yards are set, the Zoning Resolution says no building or other structure may be built above ground level in a required yard or rear yard equivalent unless it is a listed permitted obstruction (ZR 23-313). The list is layered. ZR 23-311 covers items allowed in every yard, court and required open area. ZR 23-312 adds items allowed in any yard or rear yard equivalent. ZR 23-341 adds more for rear yards and rear yard equivalents only. Courts have their own list in ZR 23-351, and commercial and manufacturing districts use ZR 33-23 and ZR 43-23, which pull in the residential lists and add their own.

Each item comes with a size cap, and the caps are where projects get caught. Below are the limits exactly as the current text states them, last amended December 5, 2024 with City of Yes for Housing Opportunity.

Allowed in every yard, court and open area (ZR 23-311)

Added for any yard in residence districts (ZR 23-312)

Front yard fence
4 ft6 ft on part of one corner lot front yard
Rear or side wall
8 ftnot roofed, 4 ft in a front yard
Mechanical equipment
25%of a required yard; 25 sq ft max in a front yard
Above-grade pool
8 ftrear yard only, never in a front yard
What yards does your lot need?

Zohgo shows the zoning district, FAR, height and setbacks for any NYC address in about a minute. Free to start, sign in with Google or Apple.

Check any NYC address free on Zohgo

Added for rear yards and rear yard equivalents (ZR 23-341)

ObstructionLimit in the rear yardSection
Shed, tool room or storage building10 ft above the yard levelZR 23-341
Accessory greenhouse1 story or 15 ft, whichever is less; 25% of the required rear yardZR 23-341
Parking structure for a 1- or 2-family house10 ft high, detached from the houseZR 23-341
Parking structure for other residential buildings15 ft above base planeZR 23-341
Solar on the roof of a permitted rear-yard structure4 ft; 18 in on a detached accessory structure or a roof sloped over 20 degreesZR 23-341
Solar canopy over open parking15 ft above adjoining gradeZR 23-341
Breezeways, fire escapes, play and drying equipmentListed, no size capZR 23-341
Unenclosed balconyPer ZR 23-62 (see below)ZR 23-341, 23-62

Rear yards can also take residential space in two specific cases: senior housing common space in R6 to R12 (not R6B, R7B or R8B) within 100 feet of a wide street, limited to one story or 15 feet, and portions of a single- or two-family home such as an ancillary dwelling unit, limited to one-third of the rear yard. The ADU rules are covered in our NYC ADU guide. One catch: a rear yard equivalent that is also a required front or side yard can only hold what that front or side yard allows (ZR 23-341).

Balconies: the ZR 23-62 limits

Balconies get their own section. Inside a required yard, court or open area a balcony may project no more than one third of the depth of that area or 7 feet, whichever is less, may cover no more than 10 percent of the required open area, and its aggregate width at any story may not exceed 50 percent of the wall it projects from. Railings top out at 4 feet 6 inches and parapets at 4 feet. The balcony must be at least 13 feet above curb level, except on residential buildings no taller than 35 feet, where it may start at the second floor but not below 7 feet (ZR 23-62).

Worked example: a 25 x 100 ft row house lot in R5B

Say the building leaves a 30 foot rear yard, the depth ZR 23-342 requires for an attached building on a lot narrower than 40 feet. The required rear yard is 25 x 30 = 750 square feet.

Commercial and manufacturing districts

In C and M districts, ZR 33-23 and ZR 43-23 start from the residential lists in ZR 23-311 and ZR 23-341 and add their own. In any yard: fences, open accessory parking, steps, unroofed walls up to 8 feet, and mechanical or energy equipment up to 23 feet above curb level. In rear yards, the big one is a non-residential building of one story, up to 23 feet above curb level, plus accessory parking structures to 23 feet. In C7 districts and M districts with an A suffix that ground-floor obstruction may be two stories and 30 feet. Rooms for living or sleeping never count as an obstruction.

This page covers obstructions in yards. Required yard depths themselves, and the separate list of obstructions allowed above height and setback limits (ZR 23-41), are different rules. Special districts and landmarks can add limits. Check the current text before you file.

Permitted obstructions FAQ

Can I put an AC condenser in my rear yard?

Yes. Accessory mechanical and energy infrastructure equipment is a permitted obstruction in any yard if it is screened, covers no more than 25 percent of the required yard, and in R1 to R5 stays under 10 feet in rear and side yards (5 feet in front yards, where it is also capped at 25 square feet). In R6 to R12 the height cap is 15 feet (ZR 23-312).

How tall can a shed be in a rear yard?

A shed, tool room or similar storage structure in a required rear yard or rear yard equivalent may be up to 10 feet above the level of the rear yard (ZR 23-341).

How far can a balcony project into a yard?

No more than one third of the depth of the yard or 7 feet, whichever is less, covering no more than 10 percent of the required open area, with aggregate width no more than 50 percent of the wall it projects from. Balconies are not allowed in side yards or within 5 feet of a side or rear lot line in a rear yard (ZR 23-62, 23-312).

How high can a front yard fence be?

4 feet above adjoining grade. On a corner lot, a fence or wall may be up to 6 feet in the part of one front yard between a side lot line and the extension of the house's side wall (ZR 23-312).

Can eaves overhang the side yard?

Yes. Eaves, gutters and downspouts may extend into a yard up to 16 inches or 20 percent of the yard's width, whichever is less (ZR 23-311).

What can go in a rear yard in a commercial district?

Besides the residential lists, a non-residential building of one story and no more than 23 feet above curb level, accessory parking structures up to 23 feet, and equipment up to 23 feet. In C7 the ground-floor obstruction may be two stories and 30 feet (ZR 33-23).

Related pages

Sources

Residential yard obstruction sections were last amended December 5, 2024 (City of Yes for Housing Opportunity).